Use Océ Colorado 1650 prescribed:
Microflex gloves for handling ink
Foams and swabs
Matrix plate cleaning tool
Cleaning liquid (Cleaner MB - methyl benzoate)
For information on the prescribed maintenance materials, see List of Océ Colorado 1650 maintenance materials.
Wear the prescribed gloves when contact with ink or maintenance materials is possible. Gloves should always overlap sleeves. Follow the Safety Data Sheets (SDS) guidelines carefully in order to ensure maximum safety.
Use the prescribed cleaning liquid. Do not use any other cleaners.
Do not use any external light source to prevent curing of the ink and damage to the printheads.
Press until you lift the printhead carriage up very lightly. When you press too hard you will damage the printheads and carriage.
|
When accumulated ink between the printheads is visible, you have to perform the cleaning action again from step 8 with a new foam. |
|
When only a light stamp mark is visible on the foam, you can continue the cleaning action. |
Do not touch the nozzle plates of the printhead. When you touch the nozzle plates you can damage the printhead.
Make sure to end the cleaning procedure within 5 minutes, when you use the cleaning liquid. The printer has to perform automatic maintenance after, to make sure the cleaning liquid does not damage the printheads.
Use as many swabs as necessary.
Make sure all covers are closed correctly to prevent cured ink in your system.