When you see pollution on the M&C scanner, immediately clean the scanner.
Cleaning the M&C scanner has to be done once a week.
Use Océ Colorado 1650 prescribed:
Microflex gloves for handling ink
Lint free cloths
Cleaning liquid (IPA)
For information on the prescribed maintenance materials, see List of Océ Colorado 1650 maintenance materials.
Wear the prescribed gloves when contact with ink or maintenance materials is possible. Gloves should always overlap sleeves. Follow the Safety Data Sheets (SDS) guidelines carefully in order to ensure maximum safety.
Touch the printhead carriage on the covered area only, otherwise you can damage the printheads.
Do not use any external light source to prevent curing of the ink and damage to the printheads.
Only clean the glass plate of the M&C scanner. Do not touch the nozzle plates of the printhead. When you touch the nozzle plates you can damage the printhead.
Use the prescribed cleaning liquid. Do not use any other cleaners.
This cleaning liquid (IPA) is not used for cleaning the matrix plate, wiper and clean wall, maintenance drawer and heated parts of the maintenance station.