The following table lists the generic PCL5e commands which are supported by the PRISMAsync Print Server.
Function |
Parameter |
PCL command |
---|---|---|
Universal exit/start of PJL |
None |
Esc.%-12345X |
Reset |
None |
<Esc>E |
Number of copies |
1-99999 |
<Esc>&l#X |
Simplex/Duplex |
Simplex |
<Esc>&l0S |
Duplex Long Edge |
<Esc>&l1S |
|
Duplex Short Edge |
<Esc>&l2S |
|
Left Offset Registration |
# of Decipoints |
<Esc>&l#U |
Top Offset Registration |
# of Decipoints |
<Esc>&l#Z |
Units of Measure |
Dots/inch |
<Esc>&u#D |
Page Side |
Next Side |
<Esc>&a0G |
Front Side |
<Esc>&a1G |
|
Back Side |
<Esc>&a2G |
|
Job Separation |
None |
<Esc>&l1T |