CCI signals

Supported CCI signals

The following signals of the CCI are supported:

  • ENABLE signal (credit / no credit signal)

    The ENABLE line is active when there are one or more credits available. The line becomes inactive when no more credits are available.

  • COUNT_PULSE signal

    COUNT_PULSE decreases the available credits with one. When there are no credits left the ENABLE lines becomes inactive.

    No credits are available when a user takes out the CCD card.

The TEST_DEBIT and HOLD_CARD signals are not supported.

Timing

Timing specification on the COUNT_PULSE signal for the Océ VarioPrint 6000 Series:

  • Pulse duration > 50 ms

  • Pulse repetition < 10 Hz

The total time needed to count the largest format may not be larger than the time required to print the smallest format. Else, the next click would have to take place during the previous click.

Service diagnostics

The service engineer can test the CCD:

  • To test the ENABLE signal, a simple input test is available:

    24-2-001: Input Copy Control Interface ENABLE signal.

  • To test the COUNT_PULSE signal, a simple output test is available:

    24-2-002: Input Copy Control Interface COUNT_PULSE signal.

  • To test the COUNT_PULSE pulse, an output test limited on time is available:

    24-2-003: Input Copy Control Interface COUNT_PULSE pulse.