The ionizer bar is mounted by default to accommodate media up 13mm (0.5 inches) in height. If you need to use media that has a thickness of greater than 13mm you will have to reverse the mounting brackets. When the brackets are reversed the maximum thickness of media that can be used with the ionizer bar is 38mm (1.5 inches).
Procedure
-
Turn off the printer power switch.
-
Press down on the ionizer bar first from one end and then the other to release the bar from all four brackets.
Remove Static Bar
-
Loosen the bracket mount screw and then slide the bracket up in the keyed slot to remove it.
Bracket Mounted Low
-
Turn the bracket 180 degrees and then fit the other keyed slot over the bracket screw.
-
Slide the bracket mount until the screw is located in the smaller end of the keyed slot.
Bracket Mounted High
-
Make sure the bracket is level an then tighten the bracket mount screw.
-
Repeat Steps 3 to 6 until all four mounts are reversed.
Results
The printer can now use media with a maximum thickness of 38mm (1.5 inches).