Use Océ Colorado 1640 prescribed:
Nitrile gloves for handling ink
Lint free cloths and swabs
Cleaning liquid (Cleaner MB - Methyl benzoate)
For information on the prescribed maintenance materials, see List of Océ Colorado 1640 maintenance materials.
Wear the prescribed Océ Colorado 1640 nitrile gloves.
You can wear the Microflex gloves for an hour after they have been contaminated with ink. After an hour you must put on new gloves.
You can only wear the Ansell Touch N Tuff gloves for ten minutes after they have been contaminated with ink. After ten minutes you must put on new gloves.
Use the prescribed cleaning liquid. Do not use any other cleaners.
If necessary, dampen a swab with the cleaning liquid to remove any remaining ink.
Be careful to touch, the wiper can be hot.
Only use the cleaning liquid cleaner MB - Methyl benzoate in combination with swabs. Do not use a lint-free cloth.
Make sure you do not damage the rubber wiper tips.
Make sure the wiper is still correctly placed, after cleaning. For more information, see Replace the wiper.
Be careful to touch, the clean wall can be hot.
If necessary, dampen a swab with the cleaning liquid to remove any remaining ink.
Only use the cleaning liquid cleaner MB - Methyl benzoate in combination with swabs. Do not use a lint-free cloth.
Make sure the clean wall does not click out of the holder.
If necessary, dampen a swab with the cleaning liquid to remove any remaining ink.
Only use the cleaning liquid cleaner MB - Methyl benzoate in combination with swabs. Do not use a lint-free cloth.
Do not clean the black top cover of the clean wall with cleaning liquid to prevent deterioration of paint. When the cover or the surrounding area is polluted, clean according to the cleaning guidelines. For more information, see Guidelines for cleaning uncured ink.
Make sure all covers are closed correctly to prevent cured ink in your system.