The MC scanner is used for the measurement of printed test patterns. The MC scanner must be cleaned regularly.
When you see pollution on the MC scanner, immediately clean the scanner.
Cleaning the MC scanner has to be done at least once a month.
Video: Clean the MC scanner
When you get error 5713: advance media correction not working, most probably the MC scanner is polluted, clean the scanner.
Use Colorado M-series prescribed:
Microflex gloves for handling ink
Lint free cloths
Cleaning liquid (IPA)
For information on the prescribed maintenance materials, see List of Colorado M-series maintenance materials.
Wear the prescribed gloves when contact with ink or maintenance materials is possible. Gloves should always overlap sleeves. Follow the Safety Data Sheets (SDS) guidelines carefully in order to ensure maximum safety.
Do not use any external light source to prevent curing of the ink and damage to the printheads.
Only clean the glass plate of the MC scanner. Do not touch the nozzle areas of the printhead. When you touch the nozzle areas you can damage the printhead.
Use the prescribed cleaning liquid. Do not use any other cleaners.
This cleaning liquid (IPA) is not used for cleaning the maintenance drawer and heated parts of the maintenance station.
Make sure all covers are closed correctly to prevent cured ink in your system.