Loading

Can I do job management and printer configuration during synchronization

Job management on the control panel and PRISMAsync Remote Manager during synchronization

When a synchronization is running, users at the control panel or in PRISMAsync Remote Manager are still able to change resources and settings of the synchronization area.

However, these changes are not included in the synchronization data. This can lead to a synchronization failure when there are dependencies between synchronized resource entries and not synchronized resource entries.

Advice

Ensure that:

  • The cluster printers are not printing jobs.

  • There are no waiting or scheduled jobs.

  • Users are not editing jobs on the control panel or in PRISMAsync Remote Manager.

  • Users are not configuring one or more cluster printers.

Printer configuration on the Settings Editor during synchronization

When a synchronization is running, users are not able to see the Settings Editor options for 15 minutes.

All other configuration tasks that can be done from the control panel and involve the resources are disabled as well. For example, during synchronization you cannot create backups or restore a user configuration.

NOTE

After 15 minutes the Settings Editor can be accessed again, although the synchronization that includes a large amount of resource entries can still be running.

Advice

When a synchronization takes more than 15 minutes, avoid that users change Settings Editor resources and settings.