Loading

Slipping media during calibration

Introduction

When you are calibrating a smoother or flexible media, the media can start to slip on the platen resulting in an inaccurate calibration. Misalignment observed on the calibration prints can indicate the problem. Follow the procedure below to improve media transportation during the calibration process. You can stop at any time in the procedure when the problem is solved.

Procedure

  1. Remove the media from the paper path. Remove media from the paper path.
  2. Make sure the printer platen is clean. Clean the platen.
  3. Decrease the [Vacuum power] settings in the RIP:
    1. First, define an additional leading strip of 40 cm. Then, decrease the vacuum power with steps of 10% until a minimum value of 30% for zones D and E.
    2. If this is not sufficient decrease the vacuum power with steps of 10% until a minimum value of 30% for zones B and C.

      Do no decrease the vacuum power of zone A.

    NOTE

    When you decrease the [Vacuum power] too much, media can come loose from the printer platen resulting in media touches as well.

  4. Reload and perform media calibration. Calibrate the media.
  5. Observe the calibration prints before you decrease the vacuum power again. Change the media settings.

    For each step you decrease and have changed the setting: reload and calibrate the media again.

  6. When the problem remains, use tight winding for this media. Print and wind with a tension bar.