Configuration |
Dimensions printer (W x D x H) |
Minimal floor area |
Minimal room height |
Minimal volume |
---|---|---|---|---|
Standard |
880 cm x 275 cm x 240 cm / 29 x 9.2 x 7.1 ft |
1,040 cm x 575 cm / 34.2 x 18.1 ft |
300 cm / 118" |
205 m3 / 12,509,867 in3 |
The areas shown in the illustration above must be free of obstacles. Users must be aware that drawers of the Paper Input Module and the High Capacity Stacker can open automatically.
Depending on the installed Paper Input Modules, High Capacity Stackers and other finishing devices, the floor plan may look different.
Configuration |
Weight |
Surface load |
Floor evenness |
---|---|---|---|
Standard |
400 kg / 881 lb |
400 kg/m2 12 N/mm2 |
Class 5 floor (NEN2747) |
Condition |
|
---|---|
Temperature* |
20oC - 26oC / 68oF - 78.8oF |
Relative humidity* |
40% - 60% |
Air pressure |
840 - 1060 mbar |
Compressed air |
8 bar; 500 liters/min |
Power consumption |
Maximum 37.5 kWh For (80 g/m² / 20 lb bond) media: 24.4 kWh |
Power requirements Europe |
230 V; 3 phases star; 80 A; 100 A per phase Device fuse: 3 x 100 A |
Power requirements USA |
208 V; 3 phases delta; 160 A per phase or 240 V; 3 phases delta; 140 A per phase or 277 V; 3 phases star; 65 A per phase Device fuse: 3 x 191 A, 3 x 175 A, 3 x 82 A |
*Do not allow conditions in the print room to change suddenly. Keep doors to adjacent rooms closed. Use accurate equipment to measure the conditions on a regular basis.
Condition |
|
---|---|
Exhaust air production |
1,500 m3 per hour / 91,535,616 in3 per hour |
Heat production |
13 kW |
Moisture production |
300 mL per hour - 400 mL per hour |