Loading

Refill the chiller

Introduction

You can refill the chiller without service assistance.

About this task

Refill the chiller when the fluid level is near the bottom of the green zone on the level gauge glass. See Vacuum the chiller and check the fluid level.

Before you begin

Use Colorado M-series prescribed:

  • Demineralized water

  • Pouring can

  • Screwdriver (Torx-25)

NOTE

For information on the prescribed maintenance materials, see List of Colorado M-series maintenance materials.

IMPORTANT

Only refill one liter of demineralized water. When you use more, the liquid can spill and damage the machine.

Procedure

  1. On the operator panel, tap on the [System] icon on the right.
  2. Tap on [Power management].
  3. Tap on [Power off].

    The system shuts down.

  4. When the system has shut down, switch the power switch to the 'off' position.
  5. Pull out the two power supply plugs from the sockets.
  6. Go to the chiller side and locate the cover under the fan.
  7. Unscrew the left and right screws on top of the cover with the Torx-25.
  8. Lift the cover a little up and towards you (1), then lift it up fully and take it out (2)
  9. Locate the lid on top of the chiller.
  10. Twist to remove the lid.
  11. Pour one liter of demineralized water from the bottle in the pouring can.
    IMPORTANT

    Use demineralized water, do not use any other liquid.

  12. Place the pouring can on the chiller and fill the tank with the liquid.
    NOTE

    Check the level gauge glass to ensure that you do not refill beyond the top of the green zone.

  13. Close the lid, twist it on tightly.
  14. Place the cover back into position.
  15. Fasten the left and right screws on top of the cover.
  16. Plug the two power supply plugs back into the sockets.
  17. Switch the power switch to the 'on' position.