Loading

Fix "density not within required range" error

In exceptional cases the shading correction procedure fails with a "density not within required range" message. Then, perform the correction procedure to fix the problem.

Procedure

  1. Touch [System]  → [Colour adjustment]  → [Select printer calibration procedures].
  2. Select [Auto gradation adjustment].
  3. Select [Shading correction].
  4. Touch [Start printer calibration].
  5. Follow the instructions on the control panel.
  6. Touch [System]  → [Colour adjustment]  → [Select printer calibration procedures].
  7. Deselect [Shading correction].
  8. Select [Auto gradation adjustment].
  9. Touch [Start printer calibration].
  10. Follow the instructions on the control panel.
  11. Close the menu.

What to do next

When the [Shading correction] procedure still fails, contact your Service organisation.