It is advised to clean the ink unit regularly to keep the printer in the best condition. You can clean the ink unit when you replace a bottle or during periodic maintenance.
Use Océ Colorado 1640 prescribed:
Nitrile gloves for handling ink
Lint free cloths
Cleaning liquid (IPA)
For information on the prescribed maintenance materials, see List of Océ Colorado 1640 maintenance materials.
Wear the Océ Colorado 1640 prescribed nitrile gloves. You can only wear the gloves for ten minutes. After ten minutes you must put on new gloves to prevent contact with the ink.
Use the prescribed cleaning liquid. Do not use any other cleaners.
The handle is located left of the bottle you want to replace.
If preferred and possible, you can repeat the steps to take out all bottles.
If necessary, dampen a swab with the cleaning liquid to remove any remaining ink.
If preferred and possible, you can place new bottles and refill ink. The order of the bottles from left to right is YCMK. For more information, see Refill ink.