Arizona 6100 series printers, like all piezoelectric drop-on-demand printers, introduce a certain amount of cured ink particulate and chemical emissions into the atmosphere during printing. These emissions can have an impact on operator comfort and safety.
Canon Production Printing has strict standards for operator comfort and safety that often exceed the minimum legal requirements, by design. In order to comply with these standards for operator comfort and safety, all Canon companies are required to include an air filtration system in the configuration of each Arizona 6100 Series printer installed at a customer site, without exception. We have found an air filtration system that meets the functional requirements and is available in specific models that meet the necessary electrical and environmental requirements of most countries. Confirm with your local sales representative that there is a solution for your area. Also check the Arizona 6100 Site Preparation Guide or this section to view the recommended ventilation specifications.
The Duster 3000FC (FC = fume control) system is manufactured in Vancouver, Canada by Island Clean Air. It is designed to filter the air in the room at an extraordinary rate of 85 cubic meters/minute (3,000 cfm) and features two levels of particulate filtration and two different active carbon filtration elements for reliable entrapment of particulate and chemical emissions. The two types of particulate filters can be cleaned by vacuum cleaning and pressure washing by the operator for multiple uses before replacement. The active carbon filters require occasional replacement. This section explains how and when to clean or change the filters and maintain the Duster 3000FC.
Dimensions |
91.44 x 81.3 x 183 cm (36" x 32" x 72") |
Weight |
86 kg (188 lbs) |
Electrical |
1.3hp, 6.0A, 50Hz 220/230Vac Single Phase Explosion Proof, thermally protected Sealed Controls |
Airflow Indicator |
Digital gauge |
Power Indicator |
LED-green |
Filter Indicator |
LED-yellow |
Blower Capacity |
3000 cfm |
Outlet noise level |
Under 68db |
Prefilter |
1" (2.54 cm) Graduated Density Polyester |
Carbon Filter |
Activated carbon filter (15lbs refillable) |
Top Filter or for FC model |
0.3 micron, high surface area or 24lb Activated Carbon Filter |
Unit Body |
Galvanized steel, Powder Coated |
Warranty |
1 year |
Certification |
CE / UKCA |
Note: Specifications subject to change without notice. |
Air Filtration SystemMinimum Specifications |
Metric (SI) |
Imperial |
---|---|---|
Blower Capacity (air flow rate) |
85 m3/min |
3000 CFM (ft3/min) |
Particulate Filtration (smallest filtered particle) |
1 µ |
0.00004 inches |
Total Activated Carbon Filtration (by mass) |
32 kg |
70 lbs |
Air intake height (maximum, measured from floor) |
<90 cm |
<36 inches |
Emissions from UV inkjet printers are denser than air. Therefore, any air filtration system used in conjunction with the printer must have air intakes below the height of the print table.